You need to ensure that wall frames are handled carefully to prevent damage that may affect the structural integrity of the wall components. This includes:

  • lifting, loading and transporting wall frames
  • storing wall frames horizontally or vertically to protect the frames from ground-water.

2.1 Lifting, loading and transporting wall frames

Lifting, loading and transportation of steel frames shall transporting wall frames must be accomplished with sufficient care to prevent damage. Frames You must be :

  • fully

...

  • support frames in either horizontal or vertical planes

...

  • during transportation
  • take care not to put excessive pressure on joints when tying down and lifting wall frames

...

  • .

Most wall frames for single storey work may are light enough to be lifted by hand, however where .

When cranage is required , sling you need to ensure slings are:

  • attached to wall frames at plate and stud connections
  • located at equal distances from the frame centreline
  • approximately one-third to one-half of the frame length apart.

Image Added

Figure 2.1.1 Lifting frames using a crane

Image Added

Figure 2.1.2 Frames ready to be unloaded

When a crane is used to unload, suitable lifting methods are required to minimise racking loads or local distortion of members.

Slings should be located at equal distances from frame centrelines and be approximately one-third to one-half the frame length apart.

Warning
titleImportant

Take great care not to damage components when maneuvering any materials by hand. Damaged components may affect structural integrity so all components should be inspected on arrival to site. 

2.2

...

Storing wall frames

Wall frames stored on-site should must be blocked above firm ground to protect them from ground water. You can store frames either:

  • vertically
  • horizontally.

Vertical storage

Frames are Vertically stored vertically frames should be supported at the designed support locations in a manner that prevents tipping or toppling as shown in . See Figure 2.2.1.

Figure 2.2.1 Frames stacked vertically

Horizontal storage

Frames Horizontally stored horizontally frames should be supported using blocking at 1.0m to 1.5m centres or as required at joints to prevent bending of the frames as shown in . See Figure 2.2.2.