For hold down anchor capacity, refer to manufacturer's information. Suitable hold down anchors are to be provided to resist the uplift forces defined in Table calculated by the ENDUROCADD® software or as defined in Tables 2-5 of Section 3.3.1 of the ENDUROWALL® Building System Design Manual.

...

For hold down anchor capacity, refer to manufacturer's information. Suitable hold down anchors are to be provided to resist the uplift forces by the ENDUROCADD® software or as defined in Tables 2-5 of Section 3.3.1 of the ENDUROWALL® Design Manual.  Building System Design Manual. 

Image Added



Stud Thickness (mm)


Plate thickness (mm)

90mm sections75mm sections170mm sections1
Uplift capacity with 40x40x5mm2 washerUplift capacity with 24mm dia. bolt head or washerUplift capacity with 40x40x5mm2 washerUplift capacity with 24mm dia. bolt head or washerUplift capacity with 40x40x5mm2 washerUplift capacity with 24mm dia. bolt head or washer
0.750.7515.0kN6.0kN9.09kN4.0kN7.9kN3.5kN
1.01.021.0kN15kN18.49kN11.25kN17kN10.3kN
1.21.230.0kN19kNN/ANANANA

1 75mm and 70mm sections require the washers to be installed hard up against the web of the stud to ensure direct load transfer from the bent tab to the structure underneath via the bolt

2 40x40x5mm washers may be substituted with 38x38x5mm washers

Tie-down - Masonry anchors with bracket and washer (high uplift capacity - 12.5kN Limit State)

For hold down anchor capacity, refer to manufacturer's information. Suitable hold down anchors are to be provided to resist the uplift forces by the ENDUROCADD® software or as defined in in Tables 2-5 of Section 3.3.1 of the ENDUROWALL® Building System Design Manual. 

...

For hold down anchor capacity, refer to manufacturer's information. Suitable hold down anchors are to be provided to resist the uplift forces by the ENDUROCADD® software or as defined in in Tables 2-5 of Section 3.3.1 of the ENDUROWALL® Building System Design Manual.

...

For hold down anchor capacity, refer to manufacturer's information. Suitable hold down anchors are to be provided to resist the uplift forces by the ENDUROCADD® software or as defined in Tables 2-5 of Section 3.3.1 of the ENDUROWALL® Building System Design Manual. 

...

For hold down anchor capacity, refer to manufacturer's information. Suitable hold down anchors are to be provided to resist the uplift forces by the ENDUROCADD® software or as defined in in Tables 2-5 of Section 3.3.1 of the ENDUROWALL® Building System Design Manual. 

...

For hold down anchor capacity, refer to manufacturer's information. Suitable hold down anchors are to be provided to resist the uplift forces by the ENDUROCADD® software or as defined in in Tables 2-5 of Section 3.3.1 of the ENDUROWALL® Building System Design ManualManuall

Tie-down into suspended frame floor systems

...

Hold down connection - Option 4

Transfer of Racking Loads to Internal Non-Load Bearing Bracing Walls

...

Image Removed

Transfer of Racking Loads to Internal Bracing Walls - Internal Wall Perpendicular to Trusses

...

Internal to external fixing connections (Option 1)

Image Removed

Internal to external fixing connections (Option 2)

...

There are two different brackets options that may be used for this application: a slotted internal wall wall bracket, or an internal wall bracket. Either option may be used and should be installed at a maximum of 1200mm centers.

Example 1 - Slotted Bracket on Wall Running Parallel to trusses

Image Added

A slotted internal wall bracket shall be fixed to the top plate with 4 x 10-16x16 hex head fasteners and to the truss bottom chord or trimmer with 2 x 10-16x16 hex head fasteners.

Warning

It is important that the slots in the bracket allow movement between the truss and wall frame, and the fasteners are not overtightened. The truss should be able to move on the bracket in the event there is settlement. In the event that internal non-load bearing walls run parallel with roof trusses, and trimmer section shall be installed to act as a fixing point for the slotted bracket.


Example 2 - Internal Wall Bracket Perpendicular to Trusses

Image Added

Example 3 - Internal Wall Bracket Parallel with Trusses

Image Added

The internal wall brackets can be attached to ceiling battens.

Connecting Non-Load Bearing to Load Bearing Walls

Any of the 3 options below are suitable in non-cyclonic areas.

Option 1 - Strap

Image Added

A minimum of  2 x 10-10x16 hex head fasters should be used to connect each end of the 30 x 1.0mm (min) strap. This option is used when there is no top nogging.

Option 2 - Angle

Image Added

Option 3 - Top nogging

Image Added