Fastener Requirements

IMPORTANT
Fasteners used in Structural applications must comply the ENDUROFRAME® Fastener Requirements specification which can be downloaded below.

Fastener Requirements - R2.pdf

 

Fasteners used should comply with the mechanical properties specified in the ENDUROFRAME Design Manuals. Please check with the manufacturer of frames or the help portal to confirm fastener suitability.

Picture

Description

Application

Picture

Description

Application

5/16-12 x 17 Hex Washer Trusstite
Or
17-15 x 15mm GX screw Trilobular thread form

Primary connection of truss components through pre-punched holes.

Both screws listed are suitable for the application.

#10-16x16 hex head self drilling screw.

Low strength fixing- ceiling batten fix, chord and web boxing.
Used in all wall systems

Wall fastener – M6 x 1P x 15mm Smooth Top GX screw
Wall tite
(Trilobular thread form)

Connecting wall frame components together through pre-punched holes. Used in ENDUROWALLâ„¢ FRAMING SYSTEM,

#12-14x20 hex head self drilling screws

General Framing Screw- Roof, Wall and Floor frame installation
Used as reinforcing in truss manufacture.

M6,0 x1P x 18,0 Smooth Top Gx Teks

Stiffening stud to plate connections and connecting lintels to plates

M6.5 – 12 x 42 Hex Head Self Drilling Screw

Connecting smart rafters to truncated truss top chords.

The use of the correct fasteners in the quantities shown in the truss fabrication drawings are essential to ensure the design capacity of the trusses are achieved.